HOME | 中文站点 | ENGLISH

Welcome to Beijing roloo technology Co.,Ltd

优冷动态more

BIOLOGY SAFE BOX|PCR COOLER|ICE PACK|VACCINE ICE CHEST

Introduction

Excellent use of sample cool chest use low temperature phase change thermal storage materials provide the cold source, no electricity, ensure that all samples, drugs and biological products to keep 2 ~ 8 ℃, -12 ~ -18 ℃, -30 ~ - 55 ℃ temperature range and other needs, length of time temperature can reach 8 to 120 hours.

I produced a sample box of frozen samples in full compliance with the World Health Organization standards, good insulation, health non-toxic, lightweight and durable, safe and reliable, suitable for vaccines, biological and chemical reagents, samples of blood and a variety of transport and collection process low-temperature refrigeration.

Features

Accurate long-term temperature control, high temperature display

I produced a sample box of frozen sample products, the use of my proprietary phase change coolant technology, precision cooling temperature can be maintained in the cabinets can be a long time at a specific temperature range (such as 2 ~ 8 ℃, -12 ~ -18 ℃, -30 ~ -55 ℃, etc.), duration can reach 8 to 120 hours. Ensures accurate and reliable sample. In addition to matching the thermometer shows the temperature, it also can be equipped with temperature change of ice boxes, ice compartment below 7 ℃ color automatically shown in blue, above 7 ℃ automatically appear as white. This way, you can be more intuitive understanding of the temperature of cabinets, the use of more assured.

  • Simple operation

Excellent cold cooling module uses the company's unique ultra low temperature coolant of dry ice technology, not only from a big city like ice to buy, as long as the low-temperature refrigerator, you can use the excellent type of ultra-low temperature of dry ice cold ice, which for remote areas low-temperature transport and research institutes in the field sampling, it is a revolutionary change.

  • From aviation restrictions, can be taken on board the train

Different from ice and liquid nitrogen cooling, excellent cold temperature of dry ice sample box product unique low temperature coolant technology in the refrigeration process does not produce gas, so are not subject to airline restrictions, can be taken on board the train, more safe and convenient.

  • The cooling module can be used repeatedly, cooling temperature can be accurately

Not as one-time use of dry ice, the use of costly, which is repeated a number of low-temperature transport of goods back and forth the occasion, no doubt will greatly reduce the cost.

  • The configuration is complete, easy to operate

Matching customer requirements and quarantine in accordance with special knives, sharpener, stethoscope, surgical scissors, sealed sampling bags, retractors quarantine, sampling, knife, tweezers, thermometer, magnifying glass, blood collection, and non-slip gloves, test tubes, petri dishes and so on. Orders can be placed in quarantine equipment and quarantine seals, notes, etc., to facilitate on-site operation.

 

 

Product specifications

Model

Performance parameters

Technical parameters

Picture

RL-06C

Standard 2 ~ 8 ℃ refrigerator for 48 hours, and optional LCD temperature display, up to 72 hours can be increased with

【Outside Size】325 × 265 × 300mm
【Within Size】235 × 145 × 180mm

【Effective space】
155 × 105 × 27 ~ 180mm high

【Weight】 2.0KG
【empty Tank Capacity】6L

【insulation Materials】 PU polyurethane

Overall foaming molding process

RL-06D

Standard -12 ~ -18 ℃ freezer 36 hours, and optional LCD temperature display, up to 60 hours can be increased with

RL-06S

Standard -30 ~ -55 ℃ freezer for 12 hours, and optional LCD temperature display, with a maximum increase to 36 hours.

RL-06SK

Standard 2 ~ 8 ℃ refrigerator for 48 hours, 0 ℃ following environment-specific, to avoid freezing of samples.

RL-07C

Standard 2 ~ 8 ℃ refrigerator for 24 hours for up to 48 hours was equipped with

【Outside Size】325 × 220 × 210mm
【Within Size】230 × 185 × 170mm

【Weight】 1.4KG

【air tank volume】7L

EPS polystyrene insulation material Sandwich molding molding process

RL-07D

Standard -12 ~ -18 ℃ freezer 8 hours, for up to 24 hours was equipped with

RL-10C

Standard 2 ~ 8 ℃ refrigerator 36 hours, and optional LCD temperature display, up to 54 hours can be increased with

【Outside Size】 400 × 220 × 275mm
【Within Size】330 × 175 × 205mm

【Weight】 2.2KG

【air tank volume】10L

PU polyurethane insulation materials,Overall foaming molding process

RL-10D

Standard -12 ~ -18 ℃ freezer 18 hours, and optional LCD temperature display, up to 48 hours can be increased with

RL-10S

Standard -30 ~ -55 ℃ freezer for 12 hours, and optional LCD temperature display, with a maximum increase to 24 hours.

RL-10K

Standard 2 ~ 8 ℃ refrigerator for 48 hours, 0 ℃ following environment-specific, to avoid freezing of samples.

RL-12AC

Standard 2 ~ 8 ℃ for 48 hours refrigerated, box locks, and optional LCD temperature display, up to 72 hours can be increased with

【Outside Size】400 × 290 × 285mm
【Within Size】320 × 205 × 210mm

【Weight】 3.0KG empty

【air tank volume】 12L

PU polyurethane insulation materials,Overall foaming molding process

RL-12AD

Standard -12 ~ -18 ℃ to 36 hours refrigerated, box locks, and optional LCD temperature display, up to 48 hours can be increased with

RL-13C

Standard 2 ~ 8 ℃ refrigerator for 48 hours, and optional LCD temperature display, up to 72 hours can be increased with

【Outside Size】400 × 290 × 285mm
【Within Size】320 × 205 × 210mm

【Weight】 2.4KG

【air tank volume】13L

PU polyurethane insulation materials,Overall foaming molding process

RL-13D

Standard -12 ~ -18 ℃ freezer 36 hours, and optional LCD temperature display, up to 48 hours can be increased with

RL-13S

Standard -30 ~ -55 ℃ freezer for 12 hours, and optional LCD temperature display, with a maximum increase to 36 hours.

RL-13K

Standard 2 ~ 8 ℃ refrigerator for 48 hours, 0 ℃ following environment-specific, to avoid freezing of samples.

RL-17BC

Standard 2 ~ 8 ℃ refrigerator for 24 hours for up to 48 hours was equipped with

【Outside Size】435 × 300 × 320mm
【Within Size】340 × 200 × 245mm

【Weight】 2.6KG

【air tank volume】17L

EPS polystyrene insulation material,Sandwich molding process

RL-17BD

Standard -12 ~ -18 ℃ freezer for 12 hours, for up to 24 hours was equipped with

RL-17AC

Standard 2 ~ 8 ℃ for 48 hours refrigerated, box locks, and optional LCD temperature display, up to 96 hours can be increased with

【Outside Size】420 × 280 × 330mm
【Within Size】340 × 200 × 250mm
【Effective space】
230 × 140 × 27 ~ 250mm high

【Weight】 3.8KG

【air tank volume】17L
PU polyurethane insulation materials,Overall foaming molding process

RL-17AD

Standard -12 ~ -18 ℃ to 36 hours refrigerated, box locks, and optional LCD temperature display, up to 72 hours can be increased with

RL-17AS

Standard -30 ~ -55 ℃ freezer for 12 hours, and optional LCD temperature display, with a maximum increase to 48 hours.

RL-17AK

Standard 2 ~ 8 ℃ refrigerator for 48 hours, 0 ℃ following environment-specific, to avoid freezing of samples.

RL-28AC

Standard 2 ~ 8 ℃ refrigerator for 48 hours, and optional LCD temperature display, up to 72 hours can be increased with

【Outside Size】550 × 340 × 360mm

【Within Size】435 × 250 × 260mm

【Weight】 5.8KG

【air tank volume】28L

PU polyurethane insulation materials,Overall foaming molding process

RL-28AD

Standard -12 ~ -18 ℃ freezer 36 hours, and optional LCD temperature display, up to 48 hours can be increased with

RL-33C

Standard 2 ~ 8 ℃ for 48 hours refrigerated, box locks, and optional LCD temperature display, up to 72 hours can be increased with

【Outside Size】605 × 340 × 420mm
【Within Size】525 × 250 × 340mm

【Weight】 6.0KG

【air tank volume】33L

PU polyurethane insulation materials,Overall foaming molding process

RL-33D

Standard -12 ~ -18 ℃ to 36 hours or more frozen, box locks, and optional LCD temperature display, up to 48 hours can be increased with

RL-46AC

Standard 2 ~ 8 ℃ for 48 hours refrigerated, box locks, and optional LCD temperature display, up to 80 hours can be increased with

【Outside Size】605 × 340 × 420mm
【Within Size】525 × 250 × 340mm

【Weight】 6.0KG

【air tank volume】46L

PU polyurethane insulation materials,Overall foaming molding process

RL-46AD

Standard -12 ~ -18 ℃ to 36 hours or more frozen, box locks, and optional LCD temperature display, up to 60 hours can be increased with

RL-48C

2 ~ 8 ℃ standard 24-hour cold storage, optional LCD temperature display, up to 48 hours can be increased with

【Outside Size】 605 × 340 × 420mm
【Within Size】540 × 280 × 300mm

【Weight】 6.0KG

【air tank volume】48L

PU polyurethane insulation materials,Overall foaming molding process

RL-48D

Standard -12 ~ -18 ℃ freezer 16 hours, and optional LCD temperature display, up to 24 hours can be increased with

RL-50C

Standard 2 ~ 8 ℃ refrigerator for 48 hours, and optional LCD temperature display, up to 72 hours can be increased with

【Outside Size】615 × 410 × 390mm
【Within Size】535 × 330 × 315mm

【Weight】 6.5KG

【air tank volume】50L

PU polyurethane insulation materials,Overall foaming molding process

RL-50D

Standard -12 ~ -18 ℃ freezer 36 hours, and optional LCD temperature display, up to 48 hours can be increased with

RL-71C

Standard 2 ~ 8 ℃ refrigerator 36 hours, and optional LCD temperature display, up to 48 hours can be increased with

【Outside Size】790 × 500 × 420mm
【Within Size】580 × 360 × 340mm

【Weight】 9.0KG

【air tank volume】71L

PU polyurethane insulation materials,Overall foaming molding process

RL-71D

Standard -12 ~ -18 ℃ freezer 24 hours, and optional LCD temperature display, up to 36 hours can be increased with

RL-100C

Standard 2 ~ 8 ℃ refrigerator 36 hours, and optional LCD temperature display, up to 48 hours can be increased with

【Outside Size】750 × 460 × 440mm

【Within Size】640 × 390 × 390mm

【Weight】 9.5KG

【air tank volume】100L

PU polyurethane insulation materials,Overall foaming molding process

RL-100D

Standard -12 ~ -18 ℃ frozen more than 24 hours, and optional LCD temperature display, up to 48 hours can be increased with

RL-110C

Standard 2 ~ 8 ℃ refrigerator for 48 hours, and optional LCD temperature display, up to 72 hours can be increased with

【Outside Size】680 × 500 × 540mm

【Within Size】600 × 420 × 440mm

【Weight】 10.0KG

【air tank volume】110L

PU polyurethane insulation materials,Overall foaming molding process

RL-110D

Standard -12 ~ -18 ℃ freezer 36 hours or more, optional LCD temperature display, up to 60 hours can be increased with

 

Applications

Serum, stem cell, cell line reagents and gene class living cells and biological agents to carry and preservation

Sampling and research institutes, field sampling and transport of samples stored at low temperature

Hospital, CDC, Inspection and Quarantine Supervision sampling sampling applications

A variety of 2 ~ 8 ℃, -12 ~ -18 ℃, -20 ℃, -40 ℃ the following temperature requirements and preservation of samples carrying the sample

 

 

 

保温箱|生物安全运输箱|快餐食品保温箱|a类冷藏采样取样送样箱